Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nature ; 627(8003): 313-320, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38480964

RESUMO

Intrinsically stretchable electronics with skin-like mechanical properties have been identified as a promising platform for emerging applications ranging from continuous physiological monitoring to real-time analysis of health conditions, to closed-loop delivery of autonomous medical treatment1-7. However, current technologies could only reach electrical performance at amorphous-silicon level (that is, charge-carrier mobility of about 1 cm2 V-1 s-1), low integration scale (for example, 54 transistors per circuit) and limited functionalities8-11. Here we report high-density, intrinsically stretchable transistors and integrated circuits with high driving ability, high operation speed and large-scale integration. They were enabled by a combination of innovations in materials, fabrication process design, device engineering and circuit design. Our intrinsically stretchable transistors exhibit an average field-effect mobility of more than 20 cm2 V-1 s-1 under 100% strain, a device density of 100,000 transistors per cm2, including interconnects and a high drive current of around 2 µA µm-1 at a supply voltage of 5 V. Notably, these achieved parameters are on par with state-of-the-art flexible transistors based on metal-oxide, carbon nanotube and polycrystalline silicon materials on plastic substrates12-14. Furthermore, we realize a large-scale integrated circuit with more than 1,000 transistors and a stage-switching frequency greater than 1 MHz, for the first time, to our knowledge, in intrinsically stretchable electronics. Moreover, we demonstrate a high-throughput braille recognition system that surpasses human skin sensing ability, enabled by an active-matrix tactile sensor array with a record-high density of 2,500 units per cm2, and a light-emitting diode display with a high refreshing speed of 60 Hz and excellent mechanical robustness. The above advancements in device performance have substantially enhanced the abilities of skin-like electronics.


Assuntos
Desenho de Equipamento , Pele , Transistores Eletrônicos , Dispositivos Eletrônicos Vestíveis , Humanos , Silício , Nanotubos de Carbono , Tato
2.
bioRxiv ; 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37873341

RESUMO

Bioelectronic fibers hold promise for both research and clinical applications due to their compactness, ease of implantation, and ability to incorporate various functionalities such as sensing and stimulation. However, existing devices suffer from bulkiness, rigidity, limited functionality, and low density of active components. These limitations stem from the difficulty to incorporate many components on one-dimensional (1D) fiber devices due to the incompatibility of conventional microfabrication methods (e.g., photolithography) with curved, thin and long fiber structures. Herein, we introduce a fabrication approach, ‶spiral transformation″, to convert two-dimensional (2D) films containing microfabricated devices into 1D soft fibers. This approach allows for the creation of high density multimodal soft bioelectronic fibers, termed Spiral NeuroString (S-NeuroString), while enabling precise control over the longitudinal, angular, and radial positioning and distribution of the functional components. We show the utility of S-NeuroString for motility mapping, serotonin sensing, and tissue stimulation within the dynamic and soft gastrointestinal (GI) system, as well as for single-unit recordings in the brain. The described bioelectronic fibers hold great promises for next-generation multifunctional implantable electronics.

3.
Science ; 380(6646): 735-742, 2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37200416

RESUMO

Artificial skin that simultaneously mimics sensory feedback and mechanical properties of natural skin holds substantial promise for next-generation robotic and medical devices. However, achieving such a biomimetic system that can seamlessly integrate with the human body remains a challenge. Through rational design and engineering of material properties, device structures, and system architectures, we realized a monolithic soft prosthetic electronic skin (e-skin). It is capable of multimodal perception, neuromorphic pulse-train signal generation, and closed-loop actuation. With a trilayer, high-permittivity elastomeric dielectric, we achieved a low subthreshold swing comparable to that of polycrystalline silicon transistors, a low operation voltage, low power consumption, and medium-scale circuit integration complexity for stretchable organic devices. Our e-skin mimics the biological sensorimotor loop, whereby a solid-state synaptic transistor elicits stronger actuation when a stimulus of increasing pressure is applied.


Assuntos
Retroalimentação Sensorial , Robótica , Pele Artificial , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrônica , Pele , Transistores Eletrônicos
4.
Int J Comput Assist Radiol Surg ; 11(10): 1927-36, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27038964

RESUMO

PURPOSE: We developed and evaluated a visual compensation system that allows surgeons to visualize obscured regions in real time, such that the surgical instrument appears virtually transparent. METHODS: The system consists of two endoscopes: a main endoscope to observe the surgical environment, and a supporting endoscope to render the region hidden from view by surgical instruments. The view captured by the supporting endoscope is transformed to simulate the view from the main endoscope, segmented to the shape of the hidden regions, and superimposed to the main endoscope image so that the surgical instruments look transparent. A prototype device was benchmarked for processing time and superimposition rendering error. Then, it was evaluated in a training environment with 22 participants performing a backhand needle driving task with needle exit point error as the criterion. Lastly, we conducted an in vivo study. RESULTS: In the benchmark, the mean processing time was 62.4 ms, which was lower than the processing time accepted in remote surgeries. The mean superimposition error of the superimposed image was 1.4 mm. In the training environment, needle exit point error with the system decreased significantly for experts compared with the condition without the system. This change was not significant for novices. In the in vivo study, our prototype enabled visualization of needle exit points during anastomosis. CONCLUSION: The benchmark suggests that the implemented system had an acceptable performance, and evaluation in the training environment demonstrated improved surgical task outcomes in expert surgeons. We will conduct a more comprehensive in vivo study in the future.


Assuntos
Endoscópios , Endoscopia/métodos , Processamento de Imagem Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Animais , Desenho de Equipamento , Humanos , Instrumentos Cirúrgicos , Técnicas de Sutura , Suínos , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...